Rcon Tool
Rcon | |
---|---|
Levels: | Rcon, Modding Rcon |
Author: | Jens Erik Vaaler, Scooper_nr, SixxGunz |
- See also: Server Configuration.
CoD RconTool - A Modding Tool for Call of Duty: World At War. Manage your serversettings. Manage servers for: -Call of Duty -Call of Duty: United Offensive -Call of Duty 2 -Call of Duty 4 -Call of Duty: World at War Use CoD RconTool to: -Manage your serversettings.Keep track of ingame chat.Automatically kick players on bad. RCON utility for Miscreated a Sandbox Survival Game on CRYENGINE. Download the latest version here. Schedule recurring or specific tasks to occur Tasks can be an RCON command or javascript code; Send RCON commands; Whitelist/De-Whitelist Players; Ban/Kick Players; Keep notes and stats on players; View Game map and add custom. Funcom, it would be amazing if you guys published an official Rcon tool at some point when Rcon is available for servers. There are a few guys who write some programs like that for Rust and Ark.
Remote Control (RCON) for Conan Exiles.
- 2Configuring your server
- 3Using Rcon
Resources[edit | edit source]
- Conan Exiles uses the same network protocol as Minecraft for its remote control functionality, so you should be able to use any Minecraft-compatible rcon tool to manage your server. The one suggested in this guide is mcrcon by Tiiffi.
- Valve Developer Community: Source RCON Protocol.
Configuring your server[edit | edit source]
You have two options to configure your server to use rcon, and you can mix and match the different options between the two if you want to.
Game.ini method[edit | edit source]
Add the following section (with your modifications) to your servers Game.ini file.
Your dedicated server's Game.ini file's location is dependent on how you host it. If you are using a hosting company you can ask them for assistance, or they might already support RCON through their control panel.
If you are hosting your own, a typical location for the Game.ini could be:
Commandline method[edit | edit source]
You can also configure rcon through commandline options.
Basically all the options under the Game.ini section also function as commandline arguments, with the same type of formatting as in the Game.ini
Using Rcon[edit | edit source]
Assuming that you're using the mcrcon tool, you can connect to your server with the following command in a terminal window:
Once connected, the first command you should try is 'help':
All rcon commands used on your server will be logged to a log file in your servers Logs folder. The file will be named RconCommandLog.log
All connections will be logged in the regular ConanSandbox.log file.
Commands[edit | edit source]
Updated documentation for Rcon commands is planned.[1] |
This article is a stub. You can help Conan Exiles Wiki by expanding it. |

con 0 setstat level 60
should set the player in slot 0 to level 60.
Server Settings[edit | edit source]
This article is a stub. You can help Conan Exiles Wiki by expanding it. |
- Note: Not every setting can be changed and see the effects live. Some settings will revert back to default or last load up if not done at the correct time (like having the server offline for it to actually work correctly). When you make your ServerSettings.ini read-only, you also miss out on updates because the server will always pull in new settings (does not always work 100% - verifying files works for this and then new settings are entered in on next restart as they are loaded from default configurations - some custom edits to these files will actually hinder them from updating correctly)
Modding Rcon[edit | edit source]
Modders can add their own Rcon commands in the DevKit.
Notes[edit | edit source]
- Rcon commands introduced with Balancing Pass and Exploit Fixes (15.06.2018):
whitelistplayer <steamid>
unwhitelistplayer <steamid>
Media[edit | edit source]
References[edit | edit source]
- ↑Updated Documentation for Admin Settings and Rcon commands, Natascha Röösli - Trello, November 23, 2018
These Field Network Configuration Files are available to download.
Before downloading, please open and read the following Software License Agreement (PDF file) of the software you want to download.
You may not download and/or use this software if you do not agree to the terms of this agreement.
If you cannot view the agreement, please contact us.
Software License Agreement (PDF: 430KB)
Please download Field Network Configuration File(s) from the following list.
You may need to right-click and 'Save As…' to download a file to your computer.
If you have any problems downloading Uncompressed files, please try downloading the ZIP compressed files.
Network type | Controller, other | File name | Content | Number of ports used (I/O points) *Other notes | |
---|---|---|---|---|---|
Uncompressed file | ZIP compressed file | ||||
― | RGW-** gateway unit MSEP-C MSCON ERC3 gateway MCON RCP6S gateway REC RCON | ― | RGW_Parameter.zip | Gateway parameter setting tool | ― |
DeviceNet | RCM-GW-DV gateway unit (PCON-SE) (ACON-SE) (ERC2-SE) | There is an instruction in the manual as - EDS File to import is 'EDS_ABS_DEV_V_*_**', but please use the following EDS File. | EDS file for DeviceNet | Refer to the instruction manual | |
rcm-gw-dv.eds | rcm-gw-dv_eds.zip | ||||
(Note) The EDS File is a provisional version, so the file name may be changed at a later date. | |||||
PCON ACON PSEL-C ASEL-C SSEL-C SCON-CA PCON-CA | IAI_DEV_MUL_V_1_1.eds | IAI_DEV_MUL_V_1_1_eds.zip | |||
SCON-C | iai_scon.eds | iai_scon_eds.zip | |||
ROBONET MSEP-C MSCON ERC3 gateway | robonet_2_1.eds | robonet_eds_2_1.zip | |||
XSEL-J/K/P/Q | abs.eds | abs_eds.zip | |||
MSEP-LC MSEL XSEL-R/S XSEL-RA/SA TTA SCON-CAL ACON-CA DCON-CA PSEL-CS ASEL-CS SSEL-CS ACON-CB SCON-CB DCON-CB MCON-C PCON-CB RCP6GW RCON RSEL REC-GW | EDS_IANP3801_DN0_V_2_3.eds | EDS_IANP3801_DN0_V_2_3.zip | |||
― | |||||
E-Con | iai_econ.eds | iai_econ_eds.zip | |||
RCS-C | iai_rcs.eds | iai_rcs_eds.zip | |||
CompoNet | PCON ACON SCON-CA MSEP-C PCON-CA MSCON ERC3 gateway | IAI_CompoNet_V_1_1.eds | IAI_CompoNet_V_1_1_eds.zip | EDS file for CompoNet | Refer to the instruction manual |
MSEP-LC SCON-CAL ACON-CA DCON-CA ACON-CB SCON-CB DCON-CB MCON-C PCON-CB | EDS_IACN3802_V_1_0.eds | EDS_IACN3802_V_1_0.eds.zip | ― | ― | |
CC-Link | MSEL | - | 0x0226_MSEL-P_A_ja.zip | CSPP file for CC-Link | Refer to the instruction manual |
XSEL-J/K/P/Q *Note: XSEL-J/K controllers have been discontinued as of December 26, 2017. | HMS-ABS-CCL_1.csp | HMS-ABS-CCL_1_csp.zip | 1 Remote device (1 station) CSP file | For each 96 points or less | |
HMS-ABS-CCL_2.csp | HMS-ABS-CCL_2_csp.zip | 2 Remote Device (2 Channel) CSP File | For each 112 points or more and 192 points or less | ||
HMS-ABS-CCL_3.csp | HMS-ABS-CCL_3_csp.zip | 3 Remote Device (3 Channel) CSP File | For each 208 points or more and 256 points or less | ||
TTA | - | 0x0226_TTA_A_ja.zip | CC-Link CSPP File | Refer to the instruction manual | |
Gateway | Please follow the manual to setup Network Parameter (CC-Link) of GX Developer. | ||||
ACON-CA | ― | 0x0226_ACON-CA_A_ja.zip | ― | ― | |
DCON-CA | ― | 0x0226_DCON-CA_A_ja.zip | ― | ― | |
SCON-CAL | ― | 0x0226_SCON-CAL_A_ja.zip | ― | ― | |
PCON-C PCON-CA PCON-CB ACON-C ACON-CA ACON-CB DCON-CA DCON-CB SCON-CA SCON-CAL SCON-CB | ― | 0x0226_RCController(PositionMode)_A_ja.zip | ― | It doesn't matter which model you have, as long as you have a dedicated CSPP for your model. | |
SCON-CB-F | ― | 0x0226_RCController(ServoPressMode)_A_ja.zip | ― | ||
SCON-LC | ― | 0x0226_RCController(PLCMode)_A_ja.zip | ― | ||
MSEP-C MCON-C MSCON-C ERC3 GW RCON REC-GW | ― | 0x0226_GatewayController_A_en.zip | ― | ||
ASEL-C ASEL-CS PSEL-C PSEL-CS SSEL-C SSEL-CS XSEL-R/S XSEL-RA/SA TTA MSEL-PC RSEL | ― | 0x0226_SELController_A_ja.zip | ― | ||
CC-Link IE Field | ACON-CB/CGB | ― | CC-Link_IE.zip | ― | ― |
DCON-CB/CGB | ― | CC-Link_IE.zip | ― | ― | |
PCON-CB/CGB | ― | CC-Link_IE.zip | ― | ― | |
PCON-CFB/CGFB | ― | CC-Link_IE.zip | ― | ― | |
SCON-CB/CGB | ― | CC-Link_IE.zip | ― | ― | |
SCON-CB-F/CGB-F | ― | CC-Link_IE.zip | ― | ― | |
RCON | ― | 0x0226_RCON-GW-CIE_1.0.0_ja.zip | ― | ― | |
RSEL | ― | 0x0226_RSEL-G-CIE_1.0.0_ja.zip | ― | ― | |
REC-GW | ― | 0x0226_REC-GW-CIE_1.0.0_ja.zip | ― | ― | |
MCON-C | ― | 0x0226_MCON-C-CIE_1.0.0_ja.zip | ― | ― | |
ProfiBus | ROBONET MSEP-C MSCON ERC3 gateway | IAI0B2F.gsd | IAI0B2F_gsd.zip | GSD file for ProfiBus | ― |
MSEP-LC MSEL XSEL-R/S XSEL-RA/SA TTA SCON-CAL ACON-CA DCON-CA ACON-CB SCON-CB DCON-CB MCON-C PCON-CB RCP6GW RCON RSEL REC-GW | IAI_0CEF.gsd | IAI_0CEF.zip | |||
PCON ACON SCON-CA SSEL-C/CS PSEL-C/CS ASEL-C/CS PCON-CA | HMS_1811.gsd | HMS_1811_gsd.zip | |||
RCM-GW-PR gateway unit | hms_1003.gsd | hms_1003_gsd.zip | 256 points each | ||
XSEL-J/K/P/Q *Note: XSEL-J/K controllers have been discontinued as of December 26, 2017. | |||||
SCON-C E-Con | hms_1000.gsd | hms_1000_gsd.zip | ― | ||
RCS-C | |||||
PROFINET IO | MSEL MSEP-LC MSEP-C SCON-CAL ACON-CA DCON-CA PCON-CA SCON-CA ACON-CB SCON-CB DCON-CB MCON-C PCON-CB RCP6GW RCON RSEL REC-GW | GSDML-V2.3-IAI-IAI-PRT-20130807.xml | GSDML-V2.3-IAI-IAI-PRT-20130807.zip | GSDML file for PROFINET IO | Refer to the instruction manual |
NOTE: Please try this file if the file above does not connect. GSDML-V2.3-IAI-IAI-PRT-2013.xml | NOTE: Please try this file if the file above does not connect. GSDML-V2.3-IAI-IAI-PRT-20131103.zip | ||||
EtherNet/IP | PCON ACON SCON-CA MSEP-C PCON-CA MSCON XSEL-R/S ERC3 gateway | 368-952-EDS_ABCC_EIP_V_2_2.eds | 368-9523-EDS_ABCC_EIP_V_2_2.zip | EDS file for EtherNet/IP | Refer to the instruction manual |
XSEL-P/Q | 005A000C000E0200.eds | 005A000C000E0200.zip | |||
XSEL-RA/SA MSEP-LC MSEL TTA SCON-CAL ACON-CA DCON-CA SSEL-CS PSEL-CS ASEL-CS ACON-CB SCON-CB DCON-CB MCON-C PCON-CB RCP6GW RCON RSEL REC-GW | IANP3802-EP0_V_2_1.eds | IANP3802-EP0_V_2_1.zip | |||
EtherCAT | PCON ACON PCON-CA SCON-CA | ESI_IAI_CON ECT_V_1_04_Rev_4.xml | ESI_IAI_CON_ ECT_V_1_04_Rev_4.zip | For EtherCAT ESI file | Refer to the instruction manual *Since our EtherCAT module uses multiple versions, multiple version ESI files are posted. If you are using OMRON NJ series or Beckhoff TwinCAT2 as the host device, please download the ESI file of each Ver. It is automatically recognized by the higher-level tool during configuration. When using the Omron CJ series, it is necessary to manually select depending on the combination of Omron's tool and our EtherCAT module version, so please contact us. |
ESI_IAI_CON_ECT_V_1_07_Rev_0.xml | ESI_IAI_CON_ECT_V_1_07_Rev_0.zip | ||||
SCON-CAL ACON-CA DCON-CA | ESI_IAI_CON_ECT_V_1_07_Rev_0.xml | ESI_IAI_CON_ECT_V_1_07_Rev_0.zip | |||
ACON-CB SCON-CB DCON-CB PCON-CB | ESI_IAI_CON_ECT_V_1_07_Rev_1.xml | ESI_IAI_CON_ECT_V_1_07_Rev_1.zip | |||
SCON-CB | ESI_IAI_CON_ECT_V_1_07_Rev_2.xml | ESI_IAI_CON_ECT_V_1_07_Rev_2.zip | |||
PCON-C | ESI_IAI_CON_ECT_V_1_08_Rev_0.xml | ESI_IAI_CON_ECT_V_1_08_Rev_0.zip | |||
XSEL-R/S | ESI_IAI_SEL_ ECT_V_1_06_Rev_0.xml | ESI_IAI_SEL ECT_V_1_06_Rev_0.zip | |||
ESI_IAI_SEL_ECT_V_1_07_Rev_1.xml | ESI_IAI_SEL_ECT_V_1_07_Rev_1.zip | ||||
XSEL-RA/SA | ESI_IAI_SEL_ECT_V_1_07_Rev_1.xml | ESI_IAI_SEL_ECT_V_1_07_Rev_1.zip | |||
XSEL-R/S XSEL-RA/SA TTA MSEL-PC RSEL | ESI_IAI_SEL_ECT_V_1_08_Rev_1.xml | ESI_IAI_SEL_ECT_V_1_08_Rev_1.zip | |||
MSEP-LC MSEP-C MSCON ERC3 gateway MCON-C RCP6GW | ESI_IAI_Gateway_ECT_V_1_07_Rev_0.xml | ESI_IAI_Gateway_ECT_V_1_07_Rev_0.zip | |||
MSEP-LC MSEP-C MSCON ERC3 gateway MCON-C RCP6GW RCON REC-GW | ESI_IAI_Gateway_ECT_V_1_08_Rev_0.xml | ESI_IAI_Gateway_ECT_V_1_08_Rev_0.zip | |||
EtherCAT motion | MCON-C | ESI_IAI_MCON_ECM_V_2_01_Rev_0.xml | ESI_IAI_MCON_ECM_V_2_01_Rev_0.zip |